EGFR Mutation Analysis Kit

Cat Number: EGFR-RT52

The EGFR Mutation Analysis Kit is a highly sensitive real-time PCR assay that detects key EGFR mutations in exons 18–21, enabling accurate and efficient mutation profiling to guide targeted cancer therapy decisions.

 

  • 1% Limit of Detection (LOD)
  • 52 tests per kit
  • 2-hour turnaround time
  • Works with FFPE and fresh frozen samples
  • 8 Reactions per sample
  • Complementary EPAS analysis software
  • For research use (RUO) in the U.S
  • For in vitro diagnostic use (IVD) in the European Union
Category: Tag:

The epidermal growth factor receptor (EGFR) gene encodes a receptor tyrosine kinase that plays a central role in transmitting signals from extracellular ligands to downstream pathways involved in cell proliferation and survival. Mutations in EGFR, particularly in exons 18, 19, 20, and 21, are frequently found in various solid tumors.

The EGFR Mutation Analysis Kit is a real-time PCR-based assay designed for the specific and sensitive detection of somatic EGFR mutations. Using mutant-specific primers and fluorescent hydrolysis probes, the assay preferentially amplifies mutant DNA even in samples with a high proportion of wild-type DNA.

This highly reliable and efficient assay provides valuable insights into tumor genetics.

EntroGen’s EGFR Mutation Analysis Kit detects the following EGFR mutations:

Exon 18 Exon 19 Exon 20 Exon 21
G719A – 2156G>C 2235-2249 del 15 T790M – 2369C>T L858R – 2573T>G
G719S – 2155G>A 2235-2252>AAT del 18 S768I – 2303G>T L861Q – 2582T>A
G719C – 2155G>T 2236-2253 del 18 2307-2308 ins GCCAGCGTG
G719D – 2156G>A 2237-2251 del 15 2319-2320 ins CAC
2237-2254 del 18 2310-2311 ins GGT
2237-2255>T del 19
2236-2250 del 15
2238-2255 del 18
2238-2248>GC del 11
2238-2252>GCA del 15
2233-2247 del 15
2234-2248 del 15
2235-2246 del 12
2235-2248>AATTC
2235-2251>AATTC
2235-2252>AAT
2235-2255>AAT
2236-2248>AGAC
2236-2248>CAAC
2236-2256 del 21
2237-2252>T
2239-2247 del 9
2239-2256 del 18
2239-2248>C del 10
2239-2258>CA del 20
2240-2251 del 12
2240-2257 del 18
2240-2254 del 15
2239-2251>C del 13
2237-2253>TC
2237-2253>TTCCT
2237-2253>TTGCT
2237-2256>TC
2237-2257>TCT
2238-2252 del 15
2239-2252>CA
2239-2256>CAA
2239-2262 del 24
2248-2273>CC
2252-2275 del 24
2252-2276>A
2252-2277>AT
2253-2276 del 24
2254-2277 del 24

For More Information

The EGFR Mutation Analysis Kit follows a simple and easy to use process. It can be completed in 2 hours and follows a simple straightforward process.

EntroGenʼs EGFR Mutation Analysis Kit requires a real-time PCR instrument capable of detecting VIC and FAM fluorescent probes.

This test includes reagents required for PCR amplification/detection, as well as validated reaction controls.

Columns and reagents for DNA isolation are not included. Genomic DNA from FFPE tissues can be extracted using EntroGen pureNA® Genomic DNA Isolation Kit.

We suggest using the Internal Quality Control Assay (cat. no. IQCART50) to determine the optimal amount of input DNA prior to running this assay.